7KM3220-1BA01-1EA0
2021-01-30 11:29 Click£ºtimes
7KM1020-0BA01-1DA0
SENTRON PAC1020 96X96 mm power monitoring equipment The built-in equipment of the power distribution panel is used to measure the electric quantity. Protocol: Modbus RTU with graphic display UE Nominal* value: 400/230V 45-65Hz IE Nominal: X/5A AC Auxiliary energy: 85V-276V AC Screw type Terminal connection
7KM2200-2EA30-1CA1 PMD SENTRON PAC2200 DIN rail
SENTRON, measuring instrument, 7KM PAC2200, LCD, LL: 400 V, LN: 230 V, 5 A, recessed top rail device, 3 phase, M-Bus, apparent/effective/reactive energy, self-supply, screw terminal connection
7KM2200-2EA30-1DA1 PMD SENTRON PAC2200 DIN rail
SENTRON, measuring instrument, 7KM PAC2200, LCD, L-L: 400 V, L-N: 230 V, 5 A, recessed rail installation, 3-phase, Modbus RTU, apparent/effective/reactive energy, self-supply, screw terminal connection
7KM2200-2EA30-1EA1 PMD SENTRON PAC2200 DIN rail
SENTRON, measuring instrument, 7KM PAC2200, LCD, L-L: 400 V, L-N: 230 V, 5 A, recessed rail installation, 3-phase, Modbus TCP, apparent/effective/reactive energy, self-supply, screw terminal connection
7KM2200-2EA30-1GA1 PMD SENTRON PAC2200 DIN rail
SENTRON, measuring instrument, 7KM PAC2200, LCD, LL: 400 V, LN: 230 V, 5 A, concave top rail device, 3 phases, M-Bus + MID, apparent-/ effective / reactive energy, self-supplied, Screw joint
7KM2200-2EA30-1HA1 PMD SENTRON PAC2200 DIN rail
SENTRON, measuring instrument, 7KM PAC2200, LCD, L-L: 400 V, L-N: 230 V, 5 A, recessed rail installation, 3-phase, Modbus RTU + MID, apparent/effective/reactive energy, self-supply, screw joint
7KM2200-2EA30-1JA1 PMD SENTRON PAC2200 DIN rail
SENTRON, measuring instrument, 7KM PAC2200, LCD, L-L: 400 V, L-N: 230 V, 5 A, concave top rail device, 3 phases, Modbus TCP + MID, apparent/effective/reactive energy, self-supply, screw joint
7KM2200-2EA40-1CA1 PMD SENTRON PAC2200 DIN rail
SENTRON, measuring instrument, 7KM PAC2200, LCD, LL: 400 V, LN: 230 V, 65 A, recessed top rail device, 3 phase, M-Bus, apparent/effective/reactive energy, self-supply, screw terminal connection
7KM2200-2EA40-1DA1 PMD SENTRON PAC2200 DIN rail
SENTRON, measuring instrument, 7KM PAC2200, LCD, L-L: 400 V, L-N: 230 V, 65 A, concave top rail unit, 3-phase, Modbus RTU, apparent/effective/reactive energy, self-supply, screw terminal connection
7KM2200-2EA40-1EA1 PMD SENTRON PAC2200 DIN rail
SENTRON, measuring instrument, 7KM PAC2200, LCD, L-L: 400 V, L-N: 230 V, 65 A, recessed rail installation, 3-phase, Modbus TCP, apparent/effective/reactive energy, self-supply, screw-type terminal connection
7KM2200-2EA40-1GA1 PMD SENTRON PAC2200 DIN rail
SENTRON, measuring instrument, 7KM PAC2200, LCD, LL: 400 V, LN: 230 V, 65 A, concave top rail device, 3 phases, M-Bus + MID, apparent-/ effective / reactive energy, self-supplied, Screw joint
7KM2200-2EA40-1HA1 PMD SENTRON PAC2200 DIN rail
SENTRON, measuring instrument, 7KM PAC2200, LCD, L-L: 400 V, L-N: 230 V, 65 A, concave top rail device, 3 phases, Modbus RTU + MID, apparent/effective/reactive energy, self-supply, screw joint
7KM2200-2EA40-1JA1 PMD SENTRON PAC2200 DIN rail
SENTRON, measuring instrument, 7KM PAC2200, LCD, L-L: 400 V, L-N: 230 V, 65 A, concave top rail device, 3 phases, Modbus TCP + MID, apparent/effective/reactive energy, self-supply, screw joint
7KM3120-0BA01-1DA0
SENTRON PAC3120 LCD 96X96 mm power monitoring equipment The built-in equipment of the power distribution panel is used to measure the electric quantity. Protocol: Modbus RTU with graphic display UE Nominal: 690/400V 45-65Hz IE Nominal: X/1A or X/5A AC Auxiliary energy: 100 .. .250 V +-10% AC/DC screw terminal connection
7KM3120-1BA01-1EA0
SENTRON PAC3120 LCD 96X96 mm power monitoring equipment The built-in equipment of the power distribution panel is used to measure the electric quantity. Protocol: Modbus RTU with graphic display UE Nominal: 690/400V 45-65Hz IE Nominal: X/1A or X/5A AC Auxiliary energy: 24 .. .60 V -20/+10% DC screw terminal connection
7KM3200-0CA01-1AA0
SENTRON, measuring instrument, 7KM PAC3200T, concave top rail housing without display, LL: 400 V, LN: 230 V, 5 A, concave top rail device, 3 phases, MODBUS TCP, apparent/effective/reactive energy, Wide voltage power supply, AC/DC, screw terminal connection
7KM3200-0CA01-1AA0
SENTRON, measuring instrument, 7KM PAC3200T, concave top rail housing without display, LL: 400 V, LN: 230 V, 5 A, concave top rail device, 3 phases, MODBUS TCP, apparent/effective/reactive energy, Wide voltage power supply, AC/DC, screw terminal connection
7KM3220-0BA01-1DA0
SENTRON PAC3220 LCD 96X96 mm power monitoring equipment The built-in equipment of the power distribution panel is used to measure the electric quantity. Protocol: Modbus TCP with graphic display UE Nominal: 690/400V 45-65Hz IE Nominal: X/1A or X/5A AC Auxiliary energy: 100 .250 V +-10% AC/DC screw terminal connection
7KM3220-1BA01-1EA0
SENTRON PAC3220 LCD 96X96 mm power monitoring equipment The built-in equipment of the power distribution panel is used to measure the electric quantity. Protocol: Modbus TCP with graphic display UE Nominal: 690/400V 45-65Hz IE Nominal: X/1A or X/5A AC Auxiliary energy: 24 -60 V -20/+10% DC screw terminal connection
7KM5212-6BA00-1EA2
SENTRON, measuring instrument, 7KM PAC5100, LCD, LL: 690 V, LN: 400 V, 10 A, 3 phases, Modbus TCP, apparent / effective / reactive energy / cos phi, harmonics: 2.-40., THD, class 0.5 according to IEC61557-12 or class 0.5S according to IEC62053-22, wide voltage power supply, AC/DC, screw terminal connection
7KM5212-6CA00-1EA8
SENTRON, measuring instrument, 7KM PAC5100, concave top rail housing without display, LL: 690 V, LN: 400 V, 10 A, concave top rail device, 3 phases, Modbus TCP, apparent/effective/reactive energy/ cos phi, harmonics: 2.-40., THD, level 0.5 according to IEC61557-12 or level 0.5S according to IEC62053-22, wide voltage power supply, AC/DC, screw terminal connection
7KM5412-6BA00-1EA2
SENTRON, measuring instrument and power quality recorder, 7KM PAC5200, LCD, LL: 690 V, LN: 400 V, 10 A, 3 phase, Modbus TCP, apparent-/ effective-/ reactive energy / cos phi, harmonics : 2.-40., THD, level 0.5 according to IEC61557-12 or level 0.5S according to IEC62053-22, wide voltage power supply, AC/DC, screw terminal connection
7KM5412-6CA00-1EA8
SENTRON, measuring instrument and power quality recorder, 7KM PAC5200, recessed top rail housing, no display, LL: 690 V, LN: 400 V, 10 A, recessed top rail installation, three-phase, Modbus TCP, apparent/effective / Reactive energy / cos phi, harmonics: 2.-40., THD, level 0.5 according to IEC61557-12 or level 0.5S according to IEC62053-22, wide voltage power supply, AC/DC, screw terminal connection
TAG£º