3RV1011-1AA10 3RV1011-0KA10 3RV1011-0JA10 3RV1011-0HA10

2016-10-29 17:26      Click£ºtimes
Inquiry Photo Description Model Technical parameters Certification Remark
3RV MCB Size S00 3RV1011-1AA10 Max. Operating Voltage 690VAC

REL. 1.1-1.6A, Class 10 screw connection increased breaking capacity , Electrical Power 0.55KW, Short-circuit tripping current 19A, Breaking capacity at 415V:Icu=100KA
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
3RV MCB Size S00 3RV1011-0KA10 Max. Operating Voltage 690VAC

REL. 0.9-1.25A, Class 10 screw connection increased breaking capacity , Electrical Power 0.37KW, Short-circuit tripping current 15A, Breaking capacity at 415V:Icu=100KA
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
3RV MCB Size S00 3RV1011-0JA10 Max. Operating Voltage 690VAC

REL. 0.7-1A, Class 10 screw connection increased breaking capacity , Electrical Power 0.25KW, Short-circuit tripping current 12A, Breaking capacity at 415V:Icu=100KA
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
3RV MCB Size S00 3RV1011-0HA10 Max. Operating Voltage 690VAC

REL. 0.55-0.8A, Class 10 screw connection increased breaking capacity , Short-circuit tripping current 9.6A, Breaking capacity at 415V:Icu=100KA
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
3RV MCB Size S00 3RV1011-0GA10 Max. Operating Voltage 690VAC

REL. 0.45-0.63A, Class 10 screw connection increased breaking capacity , Electrical Power 0.18KW, Short-circuit tripping current 7.6A, Breaking capacity at 415V:Icu=100KA
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
3RV MCB Size S00 3RV1011-0FA10 Max. Operating Voltage 690VAC

REL. 0.35-0.5A, Class 10 screw connection increased breaking capacity , Electrical Power 0.12KW, Short-circuit tripping current 6A, Breaking capacity at 415V:Icu=100KA
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
3RV MCB Size S00 3RV1011-0EA10 Max. Operating Voltage 690VAC

REL. 0.28-0.4A, Class 10 screw connection increased breaking capacity , Short-circuit tripping current 4.8A, Breaking capacity at 415V:Icu=100KA
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
3RV MCB Size S00 3RV1011-0DA10 Max. Operating Voltage 690VAC

REL. 0.22-0.32A, Class 10 screw connection increased breaking capacity , Electrical Power 0.09KW, Short-circuit tripping current 3.8A, Breaking capacity at 415V:Icu=100KA
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
3RV MCB Size S00 3RV1011-0CA10 Max. Operating Voltage 690VAC

REL. 0.18-0.25A, Class 10 screw connection increased breaking capacity , Electrical Power 0.06KW, Short-circuit tripping current 3A, Breaking capacity at 415V:Icu=100KA
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
3RV MCB Size S00 3RV1011-0BA10 Max. Operating Voltage 690VAC

REL. 0.14-0.2A, Class 10 screw connection increased breaking capacity , Short-circuit tripping current 1.9A, Breaking capacity at 415V:Icu=100KA
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
3RV MCB Size S00 3RV1011-0AA10 Max. Operating Voltage 690VAC

REL. 0.11-0.16A, Class 10 screw connection increased breaking capacity , Short-circuit tripping current 1.9A, Breaking capacity at 415V:Icu=100KA
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
Moduled-Plastic Enclosure 3RV1933-1DA00 82mm width, for S2 with Aux. Contact and Shunt Release

IP55£¬with N and PE terminal lockable in 0 position 
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
Moduled-Plastic Enclosure 3RV1923-1DA00 72mm width, for S0 with Aux. Contact and Shunt Release
IP55£¬with N and PE terminal lockable in 0 position 
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
Moduled-Plastic Enclosure 3RV1913-1DA00 72mm width, for S00 with Aux. Contact and Shunt Release
IP55£¬with N and PE terminal lockable in 0 position 
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
Door coupling rotary mechanism 3RV1926-0K For S0, S2, S3, black, 330mm shaft and support bracket
IP65
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
Door coupling rotary mechanism 3RV1926-0B For S0, S2, S3, black, 130mm shaft

IP65
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
Undervoltage release 3RV1902-1AP0 230VAC, Right mount, Width 18mm
 
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
Undervoltage release 3RV1902-1DP0 210-240VAC, Right mount, Width 18mm
 
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
Undervoltage release 3RV1921-1M Signalling switch
 
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
Auxil. Switch 3RV1901-1E Transverse, 1NO + 1NC
 
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.