3RV1121-4AA10 3RV1121-1KA10 3RV1121-1JA10 3RV1121-1GA10
2016-10-29 17:21 Click£ºtimes
Inquiry | Photo | Description | Model | Technical parameters | Certification | Remark |
---|---|---|---|---|---|---|
3RV MCB Size S0 | 3RV1121-4AA10 |
Max. Operating Voltage 690VAC REL. 9-12.5A, Class 10 screw connection increased breaking capacity , Electrical Power 5.5KW, Short-circuit tripping current 150A, Breaking capacity at 415V:Icu=100KA |
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 | Other models also available, please contact us for details. | ||
3RV MCB Size S0 | 3RV1121-1KA10 |
Max. Operating Voltage 690VAC REL. 7-10A, Class 10 screw connection increased breaking capacity , Electrical Power 4KW, Short-circuit tripping current 120A, Breaking capacity at 415V:Icu=100KA |
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 | Other models also available, please contact us for details. | ||
3RV MCB Size S0 | 3RV1121-1JA10 |
Max. Operating Voltage 690VAC REL. 5.5-8A, Class 10 screw connection increased breaking capacity , Electrical Power 3KW, Short-circuit tripping current 96A, Breaking capacity at 415V:Icu=100KA |
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 | Other models also available, please contact us for details. | ||
3RV MCB Size S0 | 3RV1121-1HA10 |
Max. Operating Voltage 690VAC REL. 4.5-6.3A, Class 10 screw connection increased breaking capacity , Electrical Power 2.2KW, Short-circuit tripping current 76A, Breaking capacity at 415V:Icu=100KA |
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 | Other models also available, please contact us for details. | ||
3RV MCB Size S0 | 3RV1121-1GA10 |
Max. Operating Voltage 690VAC REL. 3.5-5A, Class 10 screw connection increased breaking capacity , Short-circuit tripping current 60A, Breaking capacity at 415V:Icu=100KA |
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 | Other models also available, please contact us for details. | ||
3RV MCB Size S0 | 3RV1121-1FA10 |
Max. Operating Voltage 690VAC REL. 2.8-4A, Class 10 screw connection increased breaking capacity , Electrical Power 1.5KW, Short-circuit tripping current 48A, Breaking capacity at 415V:Icu=100KA |
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 | Other models also available, please contact us for details. | ||
3RV MCB Size S0 | 3RV1121-1EA10 |
Max. Operating Voltage 690VAC REL. 2.2-3.2A, Class 10 screw connection increased breaking capacity , Electrical Power 1.1KW, Short-circuit tripping current 38A, Breaking capacity at 415V:Icu=100KA |
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 | Other models also available, please contact us for details. | ||
3RV MCB Size S0 | 3RV1121-1DA10 |
Max. Operating Voltage 690VAC REL. 2.2-3.2A, Class 10 screw connection increased breaking capacity , Electrical Power 1.1KW, Short-circuit tripping current 38A, Breaking capacity at 415V:Icu=100KA |
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 | Other models also available, please contact us for details. | ||
3RV MCB Size S0 | 3RV1121-1CA10 |
Max. Operating Voltage 690VAC REL. 1.8-2.5A, Class 10 screw connection increased breaking capacity , Short-circuit tripping current 30A, Breaking capacity at 415V:Icu=100KA |
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 | Other models also available, please contact us for details. | ||
3RV MCB Size S0 | 3RV1121-1BA10 |
Max. Operating Voltage 690VAC REL. 1.4-2A, Class 10 screw connection increased breaking capacity , Electrical Power 0.75KW, Short-circuit tripping current 24A, Breaking capacity at 415V:Icu=100KA |
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 | Other models also available, please contact us for details. | ||
3RV MCB Size S0 | 3RV1121-1AA10 |
Max. Operating Voltage 690VAC REL. 1.1-1.6A, Class 10 screw connection increased breaking capacity , Electrical Power 0.55KW, Short-circuit tripping current 19A, Breaking capacity at 415V:Icu=100KA |
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 | Other models also available, please contact us for details. | ||
3RV MCB Size S0 | 3RV1121-0KA10 |
Max. Operating Voltage 690VAC REL. 0.9-1.25A, Class 10 screw connection increased breaking capacity , Electrical Power 0.37KW, Short-circuit tripping current 15A, Breaking capacity at 415V:Icu=100KA |
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 | Other models also available, please contact us for details. | ||
3RV MCB Size S0 | 3RV1121-0JA10 |
Max. Operating Voltage 690VAC REL. 0.7-1A, Class 10 screw connection increased breaking capacity , Electrical Power 0.25KW, Short-circuit tripping current 12A, Breaking capacity at 415V:Icu=100KA |
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 | Other models also available, please contact us for details. | ||
3RV MCB Size S0 | 3RV1121-0HA10 |
Max. Operating Voltage 690VAC REL. 0.55-0.8A, Class 10 screw connection increased breaking capacity , Short-circuit tripping current 9.6A, Breaking capacity at 415V:Icu=100KA |
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 | Other models also available, please contact us for details. | ||
3RV MCB Size S0 | 3RV1121-0GA10 |
Max. Operating Voltage 690VAC REL. 0.45-0.63A, Class 10 screw connection increased breaking capacity , Electrical Power 0.18KW, Short-circuit tripping current 7.6A, Breaking capacity at 415V:Icu=100KA |
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 | Other models also available, please contact us for details. | ||
3RV MCB Size S0 | 3RV1121-0FA10 |
Max. Operating Voltage 690VAC REL. 0.35-0.5A, Class 10 screw connection increased breaking capacity , Electrical Power 0.12KW, Short-circuit tripping current 6A, Breaking capacity at 415V:Icu=100KA |
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 | Other models also available, please contact us for details. | ||
3RV MCB Size S0 | 3RV1121-0EA10 |
Max. Operating Voltage 690VAC REL. 0.28-0.4A, Class 10 screw connection increased breaking capacity , Short-circuit tripping current 4.8A, Breaking capacity at 415V:Icu=100KA |
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 | Other models also available, please contact us for details. | ||
3RV MCB Size S0 | 3RV1121-0DA10 |
Max. Operating Voltage 690VAC REL. 0.22-0.32A, Class 10 screw connection increased breaking capacity , Electrical Power 0.09KW, Short-circuit tripping current 3.8A, Breaking capacity at 415V:Icu=100KA |
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 | Other models also available, please contact us for details. | ||
3RV MCB Size S0 | 3RV1121-0CA10 |
Max. Operating Voltage 690VAC REL. 0.18-0.25A, Class 10 screw connection increased breaking capacity , Electrical Power 0.06KW, Short-circuit tripping current 3A, Breaking capacity at 415V:Icu=100KA |
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 | Other models also available, please contact us for details. | ||
3RV MCB Size S0 | 3RV1121-0BA10 |
Max. Operating Voltage 690VAC REL. 0.14-0.2A, Class 10 screw connection increased breaking capacity , Short-circuit tripping current 2.4A, Breaking capacity at 415V:Icu=100KA |
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 | Other models also available, please contact us for details. |