3WL1112-2CB42-1AA2 3WL1110-2CB42-1AA2 3WL1108-2CB42-1AA2
2016-10-29 17:14 Click£ºtimes
Inquiry | Photo | Description | Model | Technical parameters | Certification | Remark |
---|---|---|---|---|---|---|
3WL Fixed 4P ACB£¬with Overcurrent Release | 3WL1112-2CB42-1AA2 |
Rated Current 1250A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V)£¬630A-1600A = 65kA£¬800A-3200A = 80kA,with “ETU25B” Overcurrent Release LSI |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 4P ACB£¬with Overcurrent Release | 3WL1110-2CB42-1AA2 |
Rated Current 1000A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V)£¬630A-1600A = 65kA£¬800A-3200A = 80kA,with “ETU25B” Overcurrent Release LSI |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 4P ACB£¬with Overcurrent Release | 3WL1108-2CB42-1AA2 |
Rated Current 800A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V)£¬630A-1600A = 65kA£¬800A-3200A = 80kA,with “ETU25B” Overcurrent Release LSI |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 4P ACB£¬with Overcurrent Release | 3WL1106-2CB42-1AA2 |
Rated Current 630A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V)£¬630A-1600A = 65kA£¬800A-3200A = 80kA,with “ETU25B” Overcurrent Release LSI |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 3P ACB £¬with Overcurrent Release | 3WL1225-2CB32-1AA2 |
Rated Current 2500A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V)£¬630A-1600A = 65kA£¬800A-3200A = 80kA,with “ETU25B” Overcurrent Release LSI |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 3P ACB £¬with Overcurrent Release | 3WL1220-2CB32-1AA2 |
Rated Current 2000A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V)£¬630A-1600A = 65kA£¬800A-3200A = 80kA,with “ETU25B” Overcurrent Release LSI |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 3P ACB £¬with Overcurrent Release | 3WL1116-2CB32-1AA2 |
Rated Current 1600A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V)£¬630A-1600A = 65kA£¬800A-3200A = 80kA,with “ETU25B” Overcurrent Release LSI |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 3P ACB £¬with Overcurrent Release | 3WL1112-2CB32-1AA2 |
Rated Current 1250A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V)£¬630A-1600A = 65kA£¬800A-3200A = 80kA,with “ETU25B” Overcurrent Release LSI |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 3P ACB £¬with Overcurrent Release | 3WL1110-2CB32-1AA2 |
Rated Current 1000A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V)£¬630A-1600A = 65kA£¬800A-3200A = 80kA,with “ETU25B” Overcurrent Release LSI |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 3P ACB £¬with Overcurrent Release | 3WL1108-2CB32-1AA2 |
Rated Current 800A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V)£¬630A-1600A = 65kA£¬800A-3200A = 80kA,with “ETU25B” Overcurrent Release LSI |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 3P ACB £¬with Overcurrent Release | 3WL1106-2CB32-1AA2 |
Rated Current 630A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V)£¬630A-1600A = 65kA£¬800A-3200A = 80kA,with “ETU25B” Overcurrent Release LSI |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 4P ACB | 3WL1225-2AA42-1AA2 |
Rated Current 2500A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V)£¬630A-1600A = 65kA£¬800A-3200A = 80kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 4P ACB | 3WL1220-2AA42-1AA2 |
Rated Current 2000A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V)£¬630A-1600A = 65kA£¬800A-3200A = 80kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 4P ACB | 3WL1116-2AA42-1AA2 |
Rated Current 1600A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 4P ACB | 3WL1112-2AA42-1AA2 |
Rated Current 1250A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V)£¬630A-1600A = 65kA£¬800A-3200A = 80kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 4P ACB | 3WL1110-2AA42-1AA2 |
Rated Current 1000A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V)£¬630A-1600A = 65kA£¬800A-3200A = 80kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 4P ACB | 3WL1108-2AA42-1AA2 |
Rated Current 800A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V)£¬630A-1600A = 65kA£¬800A-3200A = 80kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 4P ACB | 3WL1106-2AA42-1AA2 |
Rated Current 630A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V)£¬630A-1600A = 65kA£¬800A-3200A = 80kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 3P ACB | 3WL1225-2AA32-1AA2 |
Rated Current 2500A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V)£¬630A-1600A = 65kA£¬800A-3200A = 80kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 3P ACB | 3WL1220-2AA32-1AA2 |
Rated Current 2000A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V)£¬630A-1600A = 65kA£¬800A-3200A = 80kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. |