3WL1216-4AA32-1AA2 3WL1220-4AA32-1AA2 3WL1225-4AA32-1AA2
2016-10-29 17:05 Click£ºtimes
Inquiry | Photo | Description | Model | Technical parameters | Certification | Remark |
---|---|---|---|---|---|---|
3WL Fixed 3P ACB £¬with Overcurrent Release | 3WL1212-4CB32-1AA2 |
Rated Current 1250A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA£¬with “ETU25B” Overcurrent Release LSI |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 3P ACB £¬with Overcurrent Release | 3WL1210-4CB32-1AA2 |
Rated Current 1000A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA£¬with “ETU25B” Overcurrent Release LSI |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 3P ACB £¬with Overcurrent Release | 3WL1208-4CB32-1AA2 |
Rated Current 800A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA£¬with “ETU25B” Overcurrent Release LSI |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 4P ACB £¬without Overcurrent Release | 3WL1363-4AA41-1AA2 |
Rated Current 6300A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 4P ACB £¬without Overcurrent Release | 3WL1350-4AA42-1AA2 |
Rated Current 5000A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 4P ACB £¬without Overcurrent Release | 3WL1340-4AA42-1AA2 |
Rated Current 4000A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 4P ACB £¬without Overcurrent Release | 3WL1225-4AA42-1AA2 |
Rated Current 3200A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 4P ACB £¬without Overcurrent Release | 3WL1225-4AA42-1AA2 |
Rated Current 2500A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 4P ACB £¬without Overcurrent Release | 3WL1220-4AA42-1AA2 |
Rated Current 2000A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 4P ACB £¬without Overcurrent Release | 3WL1216-4AA42-1AA2 |
Rated Current 1600A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 4P ACB £¬without Overcurrent Release | 3WL1212-4AA42-1AA2 |
Rated Current 1250A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 4P ACB £¬without Overcurrent Release | 3WL1210-4AA42-1AA2 |
Rated Current 1000A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 4P ACB £¬without Overcurrent Release | 3WL1208-4AA42-1AA2 |
Rated Current 800A,Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 3P ACB without Overcurrent Release | 3WL1363-4AA31-1AA2 |
Rated Current 6300A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 3P ACB without Overcurrent Release | 3WL1350-4AA32-1AA2 |
Rated Current 5000A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 3P ACB without Overcurrent Release | 3WL1340-4AA32-1AA2 |
Rated Current 4000A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 3P ACB without Overcurrent Release | 3WL1232-4AA32-1AA2 |
Rated Current 3200A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 3P ACB without Overcurrent Release | 3WL1225-4AA32-1AA2 |
Rated Current 2500A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 3P ACB without Overcurrent Release | 3WL1220-4AA32-1AA2 |
Rated Current 2000A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Fixed 3P ACB without Overcurrent Release | 3WL1216-4AA32-1AA2 |
Rated Current 1600A , Max. operating voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. |