3WL1106-2AA36-1AA2 3WL1108-2AA36-1AA2 3WL1110-2AA36-1AA2
2016-10-29 10:24 Click£ºtimes
Inquiry | Photo | Description | Model | Technical parameters | Certification | Remark |
---|---|---|---|---|---|---|
3WL Draw-out 3P ACB without Overcurrent Release | 3WL1106-2AA36-1AA2 |
Rated Current 630A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Draw-out 3P ACB without Overcurrent Release | 3WL1108-2AA36-1AA2 |
Rated Current 800A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Draw-out 3P ACB without Overcurrent Release | 3WL1110-2AA36-1AA2 |
Rated Current 1000A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Draw-out 3P ACB without Overcurrent Release | 3WL1112-2AA36-1AA2 |
Rated Current 1000A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Draw-out 3P ACB without Overcurrent Release | 3WL1116-2AA36-1AA2 |
Rated Current 1600A£¬Max. Rated Operating Voltage 690VAC |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Draw-out 3P ACB without Overcurrent Release | 3WL1220-2AA36-1AA2 |
Rated Current 2000A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Draw-out 3P ACB without Overcurrent Release | 3WL1225-2AA36-1AA2 |
Rated Current 2500A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Draw-out 4P ACB without Overcurrent Release | 3WL1106-2AA46-1AA2 |
Rated Current 630A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Draw-out 4P ACB without Overcurrent Release | 3WL1108-2AA46-1AA2 |
Rated Current 800A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Draw-out 4P ACB without Overcurrent Release | 3WL1110-2AA46-1AA2 |
Rated Current 1000A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Draw-out 4P ACB without Overcurrent Release | 3WL1112-2AA46-1AA2 |
Rated Current 1250A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Draw-out 4P ACB without Overcurrent Release | 3WL1116-2AA46-1AA2 |
Rated Current 1600A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Draw-out 4P ACB without Overcurrent Release | 3WL1220-2AA46-1AA2 |
Rated Current 2000A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Draw-out 4P ACB without Overcurrent Release | 3WL1225-2AA46-1AA2 |
Rated Current 2500A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Draw-out 3P ACB, with Overcurrent Release | 3WL1106-2CB36-1AA2 |
Rated Current 630A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA with “ETU25B” Overcurrent Release LSI |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Draw-out 3P ACB, with Overcurrent Release | 3WL1108-2CB36-1AA2 |
Rated Current 800A£¬Max. Rated Operating Voltage 690VAC |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Draw-out 3P ACB, with Overcurrent Release | 3WL1110-2CB36-1AA2 |
Rated Current 1000A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA with “ETU25B” Overcurrent Release LSI |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Draw-out 3P ACB, with Overcurrent Release | 3WL1112-2CB36-1AA2 |
Rated Current 1250A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA with “ETU25B” Overcurrent Release LSI |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Draw-out 3P ACB, with Overcurrent Release | 3WL1116-2CB36-1AA2 |
Rated Current 1600A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA with “ETU25B” Overcurrent Release LSI |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | ||
3WL Draw-out 3P ACB, with Overcurrent Release | 3WL1220-2CB36-1AA2 |
Rated Current 2000A£¬Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 630A-1600A = 50kA,2000A-2500A = 55kA with “ETU25B” Overcurrent Release LSI |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. |